R-4106A
(410 Sexy)
Lower-TFA Alternative to R-454B
Save $100 Per Jug*
EPA SNAP approved for new equipment; retrofit pending. A2L for equipment. Non-flammable for transport and storage.
*Estimated savings; compared to current market price.



R-4106A
FluoroFusion Introduces R-4106A (410 Sexy)
R-4106A is FluoroFusion's patented A2L refrigerant blend, engineered as a direct alternative to R-454B and sold under the Arctic Eagle® brand. It is EPA SNAP approved for new equipment. Retrofit approval is pending.
Performance vs. R-454B
Thermodynamic cycle analysis, NIST REFPROP v10, nine operating conditions (evaporator −25 °F to 130 °F):
-
Cooling capacity: +6.6% average (range +5.0% to +8.5%), modeled
-
Efficiency (COP): +2.7% average (range +1.4% to +3.9%), modeled
-
TFA formation: roughly a 90% reduction versus R-454B
The Compliance & Safety Advantage
R-4106A has a blend GWP of 681 (40 CFR 84.64), below the 700 GWP limit for new residential and light commercial A/C and heat pump systems. For equipment application it carries the same ASHRAE A2L classification as R-454B. For transport and storage it is classified non-flammable under DOT, OSHA, NFPA and NEC, so it isn't subject to flammable-goods limits on truck stock or in-facility storage.
Why Choose R-4106A?
-
Carry more, store more: DOT non-flammable for transport and storage
-
GWP is one number. R-4106A is designed around what a refrigerant turns into, with roughly 90% less TFA formation than R-454B
-
Made in NC USA with global components: manufactured in Clayton, North Carolina, for supply security
-
Circular economy: net GWP below 10 on a production/allocation consumption basis when formulated from reclaimed components
-
POE lubricant. Zeotropic blend: charge in the liquid phase
-
Covered by U.S. Patent 12,540,265 B2; presented at the 21st International Refrigeration and Air Conditioning Conference at Purdue, July 2026
The Numbers on R-4106A vs. R-454B
Head-to-head data across capacity, efficiency, glide, discharge pressure, LFL, TFA formation, DOT classification, and price. Every OEM objection answered point by point, with sources. Four pages.






Case Study Questionnaire
Objective: To collect comprehensive data regarding the replacement of R-454B with FluoroFusion's proprietary refrigerant R-4106A.
Both R-454B and R-4106A are A2L (mildly flammable) refrigerants. This data will be used by FluoroFusion to develop a detailed,
factual case study comparing system performance between the two refrigerants.